Book your manufacturer training with Fire Detection Shop today
Discover Complete Fire Alarm Kits Shop Now
Product | Price (ex VAT) | Quantity | Total (ex VAT) |
---|---|---|---|
|
£
ex VAT
|
£0.00
|
We Recommend
Bestseller
Code: FDS331/288
INC VAT
Code: FDS331/288
The C-TEC XFP501E/X and XFP501E/H range of 16 zone single loop addressable fire alarm panels offer high performance at a competitive price.
Simple to configure using the free to download software, each XFP panel is network connectable up to 8 panels or repeaters, making the range ideal for use in larger applications such as office blocks, shopping complexes and industrial sites as well as the traditional smaller, stand-alone applications.
Combined keypad / key switch entry to Access Levels 2 and 3
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Choose the correct protocol from the selection box above or see our complete system builder tools
Models
C-TEC XFP501E/H - Hochiki ESP protocol
C-TEC XFP501E/X - Apollo XP95/Discovery protocol
C-TEC XFP501E/CA - C-TEC CAST protocol
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two independently programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Selection of zone dependency/coincidence functions
Day/night (building occupied/unoccupied) function
Investigation delay period function
Phased evacuation facility
Alarm counter
Powerful short circuit protected loop drivers
Up to 40 loop powered 10mA sounders per loop
Integral EN54-4/A2 switch mode PSU
Combined keypad / key switch entry to Access Levels 2 and 3
Intuitive Windows based upload-download PC program.
Feature | Specification |
---|---|
Approvals/certifications | EN54-2 & 4 by the LPCB |
Protocol/compatibility | Apollo XP95/Discovery |
Mains supply | 230V 50/60Hz |
Mains rated current | 350mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA) |
Quiescent current | 50mA (loop unloaded) |
Battery size and type | 2 x 12V 3.2Ah VRLA connected in series |
No. of loop drivers | 1 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
Conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay (active when no faults are present) |
Max. switch current/voltage | 1A / 30Vdc |
Other outputs | 24V Aux. Power (19.5V min, 28V max) Protected by a resettable fuse, Max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs. Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
PC connection | Via RS232 molex connector (supplied in XFP507 upload/download software kit) |
Indicators | 2 line x 40 character backlit display, 16 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card |
Product dimensions | 380 W x 235 H x D 96mm |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30 |
Weight | 1.8kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95% |
The C-TEC XFP501E/X and XFP501E/H range of 16 zone single loop addressable fire alarm panels offer high performance at a competitive price.
Simple to configure using the free to download software, each XFP panel is network connectable up to 8 panels or repeaters, making the range ideal for use in larger applications such as office blocks, shopping complexes and industrial sites as well as the traditional smaller, stand-alone applications.
Combined keypad / key switch entry to Access Levels 2 and 3
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Choose the correct protocol from the selection box above or see our complete system builder tools
Models
C-TEC XFP501E/H - Hochiki ESP protocol
C-TEC XFP501E/X - Apollo XP95/Discovery protocol
C-TEC XFP501E/CA - C-TEC CAST protocol
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two independently programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Selection of zone dependency/coincidence functions
Day/night (building occupied/unoccupied) function
Investigation delay period function
Phased evacuation facility
Alarm counter
Powerful short circuit protected loop drivers
Up to 40 loop powered 10mA sounders per loop
Integral EN54-4/A2 switch mode PSU
Combined keypad / key switch entry to Access Levels 2 and 3
Intuitive Windows based upload-download PC program.
Feature | Specification |
---|---|
Approvals/certifications | EN54-2 & 4 by the LPCB |
Protocol/compatibility | Apollo XP95/Discovery |
Mains supply | 230V 50/60Hz |
Mains rated current | 350mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA) |
Quiescent current | 50mA (loop unloaded) |
Battery size and type | 2 x 12V 3.2Ah VRLA connected in series |
No. of loop drivers | 1 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
Conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay (active when no faults are present) |
Max. switch current/voltage | 1A / 30Vdc |
Other outputs | 24V Aux. Power (19.5V min, 28V max) Protected by a resettable fuse, Max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs. Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
PC connection | Via RS232 molex connector (supplied in XFP507 upload/download software kit) |
Indicators | 2 line x 40 character backlit display, 16 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card |
Product dimensions | 380 W x 235 H x D 96mm |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30 |
Weight | 1.8kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95% |
FDS410/230
FDS410/231
FDS200/169
FDS200/170
FDS200/171
FDS900/067P
FDS100/470P
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.