Product | Price (ex VAT) | Quantity | Total (ex VAT) |
---|---|---|---|
|
£
ex VAT
|
£0.00
|
Code: FDS331/295
INC VAT
Code: FDS331/295
The C-TEC CA416 is a CAST protocol analogue addressable optical smoke detector for use on the C-TEC CAST protocol range of fire alarm system equipment.
A high-quality smoke detector for use with C-TEC's XFP & ZFP 'CAST' protocol Addressable Fire Panels
LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13
Smart algorithms help reduce false alarms
Onboard short circuit loop isolator
Includes two 8mm x 2mm ultra-bright red LED indicating strips
Drift compensation functionality
0.16dB/m sensitivity/obscuration level
5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
Programmable multi-function status LED
Compatible with C-TEC's CA408 CAST base c/w integrated locking mechanism & ID tag
Approvals/certificationsLPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
CompatibilityCompatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.
TypeOptical (utilises an infrared light source and photodiode).
Application/operationWhen there is no smoke, light passes in front of the photodiode in a straight line. When smoke enters the chamber across the path of the IR beam, light is scattered, some of which falls on the photodiode triggering the alarm.
Sensitivity0.16dB/m.
Supply wiring2-wire, polarity sensitive.
Supply/operating voltage22 to 40V DC.
Quiescent current370A typical @ 22 to 40V DC.
Alarm current5mA typical (LEDs illuminated) @ 22 to 40V DC.
Indicators2 LED indicator strips emitting red light when in alarm offering 360 visibility. Optional remote LED.
ConnectionsVia CA408 base: 1 +Ve IN (analogue swich); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.
Product dimensions (mm)102.2mm diameter x 37mm deep (detector only); 102.2mm diameter x 57.5mm deep (detector in base).
Construction & finishWhite polycarbonate casing rated to UL94 V-2 with nylon parts.
IP RatingIP42.
Weight99g (not in base); 154g (in base).
Operating conditions/temperature-20C to +85C.
NotesRequires a CA408 CAST base. CA408R relay base also available.
The C-TEC CA416 is a CAST protocol analogue addressable optical smoke detector for use on the C-TEC CAST protocol range of fire alarm system equipment.
A high-quality smoke detector for use with C-TEC's XFP & ZFP 'CAST' protocol Addressable Fire Panels
LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13
Smart algorithms help reduce false alarms
Onboard short circuit loop isolator
Includes two 8mm x 2mm ultra-bright red LED indicating strips
Drift compensation functionality
0.16dB/m sensitivity/obscuration level
5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
Programmable multi-function status LED
Compatible with C-TEC's CA408 CAST base c/w integrated locking mechanism & ID tag
Approvals/certificationsLPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
CompatibilityCompatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.
TypeOptical (utilises an infrared light source and photodiode).
Application/operationWhen there is no smoke, light passes in front of the photodiode in a straight line. When smoke enters the chamber across the path of the IR beam, light is scattered, some of which falls on the photodiode triggering the alarm.
Sensitivity0.16dB/m.
Supply wiring2-wire, polarity sensitive.
Supply/operating voltage22 to 40V DC.
Quiescent current370A typical @ 22 to 40V DC.
Alarm current5mA typical (LEDs illuminated) @ 22 to 40V DC.
Indicators2 LED indicator strips emitting red light when in alarm offering 360 visibility. Optional remote LED.
ConnectionsVia CA408 base: 1 +Ve IN (analogue swich); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.
Product dimensions (mm)102.2mm diameter x 37mm deep (detector only); 102.2mm diameter x 57.5mm deep (detector in base).
Construction & finishWhite polycarbonate casing rated to UL94 V-2 with nylon parts.
IP RatingIP42.
Weight99g (not in base); 154g (in base).
Operating conditions/temperature-20C to +85C.
NotesRequires a CA408 CAST base. CA408R relay base also available.
FDS331/224
FDS410/195
FDS410/103
FDS410/300
FDS410/301
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.