Kentec Sigma Conventional Fire Alarm Panel | 2, 4 or 8 Zone
INC VAT
Code: FDS900/125
Kentec KL11020M2 Sigma CP Conventional Fire Control Panels with LCMU (2, 4 & 8 Zones)
The Sigma CP range of conventional fire control panels is designed for the most demanding conventional fire detection and alarm system applications.
Easy to install, the Sigma CP is available in 2, 4, and 8 detection zones. The extensive range of configuration features ensures suitability for new installations or panel replacements on older systems.
Configuration options are stored in non-volatile memory and can be easily accessed via an intuitive user interface, allowing for quick viewing and modification of system settings.
The Sigma CP control panels are compatible with most standard conventional detectors, call points, and sounders from leading brands such as Apollo and Hochiki.
2, 4, or 8 detection zones
2 sounder output circuits
Fully programmable via intuitive menu options
Adjustable sounder delay time
3 on-board relay outputs
Class change input for school and industrial settings
Flexible sounder configuration options
Zonal sounder delay – detectors only or call points only
Coincidence input selection for enhanced alarm verification
I.S. barrier selection by zone for intrinsically safe applications
Short circuit fire detection by zone
Non-latching & silent zone options
Zone input delay for false alarm management
Active EOL (End of Line) included
Specification | Details |
---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour (lid & box) | BS 00 A 05 grey - fine texture |
Colour (control panel & labels) | RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Fire Contract Rating | 30V DC 1 Amp |
Sounder Output Rating | 0.5A per output (max 1.6A overall) |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 6k8 5% |
Active EOL | K14606K (optional) |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
Kentec KL11020M2 Sigma CP Conventional Fire Control Panels with LCMU (2, 4 & 8 Zones)
The Sigma CP range of conventional fire control panels is designed for the most demanding conventional fire detection and alarm system applications.
Easy to install, the Sigma CP is available in 2, 4, and 8 detection zones. The extensive range of configuration features ensures suitability for new installations or panel replacements on older systems.
Configuration options are stored in non-volatile memory and can be easily accessed via an intuitive user interface, allowing for quick viewing and modification of system settings.
The Sigma CP control panels are compatible with most standard conventional detectors, call points, and sounders from leading brands such as Apollo and Hochiki.
2, 4, or 8 detection zones
2 sounder output circuits
Fully programmable via intuitive menu options
Adjustable sounder delay time
3 on-board relay outputs
Class change input for school and industrial settings
Flexible sounder configuration options
Zonal sounder delay – detectors only or call points only
Coincidence input selection for enhanced alarm verification
I.S. barrier selection by zone for intrinsically safe applications
Short circuit fire detection by zone
Non-latching & silent zone options
Zone input delay for false alarm management
Active EOL (End of Line) included
Specification | Details |
---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour (lid & box) | BS 00 A 05 grey - fine texture |
Colour (control panel & labels) | RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Fire Contract Rating | 30V DC 1 Amp |
Sounder Output Rating | 0.5A per output (max 1.6A overall) |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 6k8 5% |
Active EOL | K14606K (optional) |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.