Book your manufacturer training with Fire Detection Shop today
Discover Complete Fire Alarm Kits Shop Now
Product | Price (ex VAT) | Quantity | Total (ex VAT) |
---|---|---|---|
|
£
ex VAT
|
£0.00
|
1 items added to basket
Fike 505 Twinflex Pro² Bi-Wire Conventional Fire Alarm Panel | 2, 4 or 8 Zone
We Recommend
Bestseller
INC VAT
Code: FDS100/447
The Fike Twinflex Pro² bi-wire fire alarm panel is an adaptable and cost-effective two-wire system, available in 2-zone (505-0002), 4-zone (505-0004), and 8-zone (505-0008) versions.
Utilising Twinflex data protocol communication, this intelligent panel can differentiate between smoke detectors, heat detectors, and manual call points, ensuring precise alarm activation. Each circuit supports up to 32 devices, providing scalability for various applications.
The Twinflex Pro² is designed for ease of use, reliability, and versatility. Featuring the Fike ASD multipoint detection system, it allows the entire system to be installed using just one pair of wires per zone, simplifying installation.
The panel continuously monitors each zone for device faults, end-of-line faults, short circuits, and detector head removal. With a 500-event log storage, day/night mode functionality, and a 72-hour battery standby time, it delivers a robust and efficient fire detection solution.
4 line x 20 character LCD display
Ability to differentiate between call point or detector alarms
Checkpoint alarm verification procedure
Highlighted selection menu
Event log storing up to 500 events
3 Enhanced test modes
Allows detectors and sounders to be installed on the same pair of wires
Up to 32 devices per zone
Built-in EOL capability in all devices
7 modes of detection
Requires 2 x 3.2Ah batteries
Additional battery box available to fit 2 x 7Ah batteries.
Attribute | 2 Zone Panel | 4 Zone Panel | 8 Zone Panel |
---|---|---|---|
Dimensions (mm) | 331 x 331 x 99 | 331 x 331 x 99 | 331 x 331 x 99 |
Weight (excluding batteries) | 2.25kg | 2.28kg | 2.36kg |
Construction | VO rated ABS | VO rated ABS | VO rated ABS |
IP Rating | IP30 | IP30 | IP30 |
Cable Entry | 13 x 20mm knockouts, 1 x 50mm x 50mm pull-out tab | 13 x 20mm knockouts, 1 x 50mm x 50mm pull-out tab | 13 x 20mm knockouts, 1 x 50mm x 50mm pull-out tab |
Cable Type | 2 core 1.5mm² screened fire rated cable, 500mm (max per zone) | 2 core 1.5mm² screened fire rated cable, 500mm (max per zone) | 2 core 1.5mm² screened fire rated cable, 500mm (max per zone) |
Detector Zones | 2 max | 4 max | 8 max |
Detectors per Zone | Up to 32 devices, dependent on Device Loading Units (DLUs) not exceeding the stated maximum loading | Up to 32 devices, dependent on Device Loading Units (DLUs) not exceeding the stated maximum loading | Up to 32 devices, dependent on Device Loading Units (DLUs) not exceeding the stated maximum loading |
Device Protocol | TWINFLEX V3 + TWINFLEX pro | TWINFLEX V3 + TWINFLEX pro | TWINFLEX V3 + TWINFLEX pro |
Monitored Sound Circuits | Up to 2 (250mA) | Up to 2 (250mA) | Up to 2 (200mA) |
Monitored Relay Circuits | Up to 2 (250mA) | Up to 2 (250mA) | Up to 2 (200mA) |
Relays on Board | Common fire and common fault | Common fire and common fault | Common fire and common fault |
Operating Standard | BS EN54-2 & 4 | BS EN54-2 & 4 | BS EN54-2 & 4 |
Operating Temperature | 5° to 40°C | 5° to 40°C | 5° to 40°C |
Mains Supply Range | 230V AC, +10% - 15%, 50/60Hz | 230V AC, +10% - 15%, 50/60Hz | 230V AC, +10% - 15%, 50/60Hz |
Event Log | 500 events | 500 events | 500 events |
The Fike Twinflex Pro² bi-wire fire alarm panel is an adaptable and cost-effective two-wire system, available in 2-zone (505-0002), 4-zone (505-0004), and 8-zone (505-0008) versions.
Utilising Twinflex data protocol communication, this intelligent panel can differentiate between smoke detectors, heat detectors, and manual call points, ensuring precise alarm activation. Each circuit supports up to 32 devices, providing scalability for various applications.
The Twinflex Pro² is designed for ease of use, reliability, and versatility. Featuring the Fike ASD multipoint detection system, it allows the entire system to be installed using just one pair of wires per zone, simplifying installation.
The panel continuously monitors each zone for device faults, end-of-line faults, short circuits, and detector head removal. With a 500-event log storage, day/night mode functionality, and a 72-hour battery standby time, it delivers a robust and efficient fire detection solution.
4 line x 20 character LCD display
Ability to differentiate between call point or detector alarms
Checkpoint alarm verification procedure
Highlighted selection menu
Event log storing up to 500 events
3 Enhanced test modes
Allows detectors and sounders to be installed on the same pair of wires
Up to 32 devices per zone
Built-in EOL capability in all devices
7 modes of detection
Requires 2 x 3.2Ah batteries
Additional battery box available to fit 2 x 7Ah batteries.
Attribute | 2 Zone Panel | 4 Zone Panel | 8 Zone Panel |
---|---|---|---|
Dimensions (mm) | 331 x 331 x 99 | 331 x 331 x 99 | 331 x 331 x 99 |
Weight (excluding batteries) | 2.25kg | 2.28kg | 2.36kg |
Construction | VO rated ABS | VO rated ABS | VO rated ABS |
IP Rating | IP30 | IP30 | IP30 |
Cable Entry | 13 x 20mm knockouts, 1 x 50mm x 50mm pull-out tab | 13 x 20mm knockouts, 1 x 50mm x 50mm pull-out tab | 13 x 20mm knockouts, 1 x 50mm x 50mm pull-out tab |
Cable Type | 2 core 1.5mm² screened fire rated cable, 500mm (max per zone) | 2 core 1.5mm² screened fire rated cable, 500mm (max per zone) | 2 core 1.5mm² screened fire rated cable, 500mm (max per zone) |
Detector Zones | 2 max | 4 max | 8 max |
Detectors per Zone | Up to 32 devices, dependent on Device Loading Units (DLUs) not exceeding the stated maximum loading | Up to 32 devices, dependent on Device Loading Units (DLUs) not exceeding the stated maximum loading | Up to 32 devices, dependent on Device Loading Units (DLUs) not exceeding the stated maximum loading |
Device Protocol | TWINFLEX V3 + TWINFLEX pro | TWINFLEX V3 + TWINFLEX pro | TWINFLEX V3 + TWINFLEX pro |
Monitored Sound Circuits | Up to 2 (250mA) | Up to 2 (250mA) | Up to 2 (200mA) |
Monitored Relay Circuits | Up to 2 (250mA) | Up to 2 (250mA) | Up to 2 (200mA) |
Relays on Board | Common fire and common fault | Common fire and common fault | Common fire and common fault |
Operating Standard | BS EN54-2 & 4 | BS EN54-2 & 4 | BS EN54-2 & 4 |
Operating Temperature | 5° to 40°C | 5° to 40°C | 5° to 40°C |
Mains Supply Range | 230V AC, +10% - 15%, 50/60Hz | 230V AC, +10% - 15%, 50/60Hz | 230V AC, +10% - 15%, 50/60Hz |
Event Log | 500 events | 500 events | 500 events |
FDS340/201
FDS900/045
FDS100/452
FDS100/453
FDS330/706
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.