C-TEC XFP501E/X 16 Zone Single Loop Addressable Fire Alarm Panel - Apollo
INC VAT
Code: FDS340/036
C-TECs XFP501E/X single loop 16 zone addressable fire alarm panel offer high performance at a competitive price. Compatible with Apollo addressable devices.
Simple to configure using the free software, the XFP is interconnectable with up to 8 panels or repeaters, making the range ideal for use in larger applications such as office blocks, shopping complexes and industrial sites as well as smaller, stand-alone applications.
C-TEC XFP501E/X
Apollo XP95/Discovery protocol
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two independently programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Selection of zone dependency/coincidence functions
Day/night (building occupied/unoccupied) function
Investigation delay period function
Phased evacuation facility
Alarm counter
Powerful short circuit protected loop drivers
Up to 40 loop powered 10mA sounders per loop
Integral EN54-4/A2 switch mode PSU
Combined keypad / keyswitch entry to Access Levels 2 and 3
Intuitive Windows based upload-download PC program
Specification | Details |
---|---|
Approvals/Certifications | Certified to EN54-2 & 4 by the LPCB. |
Protocol/Compatibility | Apollo XP95/Discovery. |
Mains Supply | 230V 50/60Hz. |
Mains Rated Current | 350mA maximum. |
Internal Power Supply | 27Vdc nominal. |
Total Output Current | Limited to 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA). |
Quiescent Current | 50mA (loop unloaded). |
Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. |
No. of Loop Drivers | 1. |
Max. Loop Output Current | 500mA (25V min; 34V max). |
Max. Loop Length | 1KM. |
Max. Addressable Devices per Loop | 126. |
No. of Conventional Sounder Circuits | 2 (Max. length per circuit is 500m). |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Max. Sounder Output Current | 400mA. |
Auxiliary Relays | - 3 x Programmable Relays (programmable from C&Es). |
- 1 x Fault Relay (active when no faults are present). | |
- Volt-free single pole changeover. Max. switch current: 1A; Max. switch voltage: 30Vdc. | |
Other Outputs | 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current: 100mA. |
Auxiliary Inputs | 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage: 27V (non-latching). |
PC Connection | PC connection via RS232 Molex connector (supplied in XFP507 upload/download software kit); No printer connection available. |
Indicators | - 2 line x 40 character backlit display. |
- 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault. | |
- System Status. | |
Connections | Fixed, largest acceptable conductor size: 1mm². |
Expansion Connections | - 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. |
- Max. 8 mains per network or 8 repeaters per non-networked main. | |
- Limit: 1KM (main panel network). | |
Product Dimensions (mm) | 380 W x 235 H x 96 D (hole required for flush mounting = 367 W x 220 H x 75 D). No bezel required. |
Construction & Finish | Plastic lid and base; RAL7035 textured. |
IP Rating | IP30. |
Weight | 1.8kg (without batteries). |
Operating Conditions/Temperature | -5ºC to +40ºC. Max relative humidity: 95%. |
C-TECs XFP501E/X single loop 16 zone addressable fire alarm panel offer high performance at a competitive price. Compatible with Apollo addressable devices.
Simple to configure using the free software, the XFP is interconnectable with up to 8 panels or repeaters, making the range ideal for use in larger applications such as office blocks, shopping complexes and industrial sites as well as smaller, stand-alone applications.
C-TEC XFP501E/X
Apollo XP95/Discovery protocol
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two independently programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Selection of zone dependency/coincidence functions
Day/night (building occupied/unoccupied) function
Investigation delay period function
Phased evacuation facility
Alarm counter
Powerful short circuit protected loop drivers
Up to 40 loop powered 10mA sounders per loop
Integral EN54-4/A2 switch mode PSU
Combined keypad / keyswitch entry to Access Levels 2 and 3
Intuitive Windows based upload-download PC program
Specification | Details |
---|---|
Approvals/Certifications | Certified to EN54-2 & 4 by the LPCB. |
Protocol/Compatibility | Apollo XP95/Discovery. |
Mains Supply | 230V 50/60Hz. |
Mains Rated Current | 350mA maximum. |
Internal Power Supply | 27Vdc nominal. |
Total Output Current | Limited to 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA). |
Quiescent Current | 50mA (loop unloaded). |
Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. |
No. of Loop Drivers | 1. |
Max. Loop Output Current | 500mA (25V min; 34V max). |
Max. Loop Length | 1KM. |
Max. Addressable Devices per Loop | 126. |
No. of Conventional Sounder Circuits | 2 (Max. length per circuit is 500m). |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Max. Sounder Output Current | 400mA. |
Auxiliary Relays | - 3 x Programmable Relays (programmable from C&Es). |
- 1 x Fault Relay (active when no faults are present). | |
- Volt-free single pole changeover. Max. switch current: 1A; Max. switch voltage: 30Vdc. | |
Other Outputs | 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current: 100mA. |
Auxiliary Inputs | 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage: 27V (non-latching). |
PC Connection | PC connection via RS232 Molex connector (supplied in XFP507 upload/download software kit); No printer connection available. |
Indicators | - 2 line x 40 character backlit display. |
- 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault. | |
- System Status. | |
Connections | Fixed, largest acceptable conductor size: 1mm². |
Expansion Connections | - 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. |
- Max. 8 mains per network or 8 repeaters per non-networked main. | |
- Limit: 1KM (main panel network). | |
Product Dimensions (mm) | 380 W x 235 H x 96 D (hole required for flush mounting = 367 W x 220 H x 75 D). No bezel required. |
Construction & Finish | Plastic lid and base; RAL7035 textured. |
IP Rating | IP30. |
Weight | 1.8kg (without batteries). |
Operating Conditions/Temperature | -5ºC to +40ºC. Max relative humidity: 95%. |
FDS900/067
FDS100/467
FDS100/456
FDS100/470
FDS600/004
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.