Book your manufacturer training with Fire Detection Shop today
Discover Complete Fire Alarm Kits Shop Now
Product | Price (ex VAT) | Quantity | Total (ex VAT) |
---|---|---|---|
|
£
ex VAT
|
£0.00
|
1 items added to basket
Kentec Sigma KL11080M2 | 8 Zone Conventional Fire Alarm Panel
INC VAT
Code: FDS900/063
The Kentec Sigma KL11080M2 is an 8-zone conventional fire alarm control panel from the Sigma CP range, designed to meet rigorous fire detection and alarm system requirements.
The extensive range of configuration features available ensures suitability for new installations or panel replacements on older systems.
Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface, which enables the configuration data to be viewed and changed efficiently.
Sigma CP control panels are compatible with most standard, conventional detectors, call points and sounders and are also compatible with ‘two wire’ detector bases from Apollo and Hochiki.
Kentec Sigma KL11080M2
8 Detection zones
2 Sounder output circuits
Fully programmable using simple menu options
Adjustable sounder delay time
3 On-board relay outputs
Class change input
Sounder configuration options
Zonal sounder delay detectors only
Zonal sounder delay call points only
Coincidence input selection
I.S Barrier selection by zone
Short circuit fire by zone
Non latching zones
Silent zones
Zone input delay
General panel configuration
Active EOL included
Specification | Details |
---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour (lid & box) | BS 00 A 05 grey - fine texture |
Colour (control panel & labels) | RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Fire Contract Rating | 30V DC 1 Amp |
Sounder Output Rating | 0.5A per output (max 1.6A overall) |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 6k8 5% |
Active EOL | K14606K (optional) |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
The Kentec Sigma KL11080M2 is an 8-zone conventional fire alarm control panel from the Sigma CP range, designed to meet rigorous fire detection and alarm system requirements.
The extensive range of configuration features available ensures suitability for new installations or panel replacements on older systems.
Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface, which enables the configuration data to be viewed and changed efficiently.
Sigma CP control panels are compatible with most standard, conventional detectors, call points and sounders and are also compatible with ‘two wire’ detector bases from Apollo and Hochiki.
Kentec Sigma KL11080M2
8 Detection zones
2 Sounder output circuits
Fully programmable using simple menu options
Adjustable sounder delay time
3 On-board relay outputs
Class change input
Sounder configuration options
Zonal sounder delay detectors only
Zonal sounder delay call points only
Coincidence input selection
I.S Barrier selection by zone
Short circuit fire by zone
Non latching zones
Silent zones
Zone input delay
General panel configuration
Active EOL included
Specification | Details |
---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour (lid & box) | BS 00 A 05 grey - fine texture |
Colour (control panel & labels) | RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Fire Contract Rating | 30V DC 1 Amp |
Sounder Output Rating | 0.5A per output (max 1.6A overall) |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 6k8 5% |
Active EOL | K14606K (optional) |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.